An FDA-approved treatment option for patients with resistant hypertension 1.

The Paradise® Ultrasound Renal Denervation System

Discover Paradise Ultrasound Renal Denervation (uRDN) – the first FDA-approved catheter-based hypertension treatment that uses ultrasound energy.

American Heart Association supports RDN for the treatment of hypertension.

Clinically proven safe and effective for uncontrolled and resistant hypertension1-3.

Met all primary
endpoints in

3/3

U.S. randomized
controlled trials1-3

RADIANCE™ RCTs
combined results

–10.4mmHg

office systolic blood

pressure at 2 months8


ACHIEVE study 4

–22.1mmHg

office systolic blood

pressure at 8 years.*(n-27)


No

impact to renal function at

2 months.5

Patients Benefited from Paradise uRDN

“Going for treatment with the Paradise Ultrasound RDN procedure was a great decision for me because now I have only one blood pressure medication. Prior to it, it was all over the board, I was taking all of those medications and my blood pressure was up and down. For me, personally, it’s a life saver.”

David, 48 years old
“Following my procedure with Paradise Ultrasound RDN, my blood pressure is better controlled.”

Candyce, 73 years old

Meet Recor Medical

Recor Medical was founded in 2009 with a singular focus: create a breakthrough therapy to treat hypertension using ultrasound technology. We developed the Paradise® Ultrasound Renal Denervation system and tested it over several years through the most rigorous randomized controlled trials. Having proved that it can effectively and safely lower blood pressure in a broad range of patients, we’re bringing this therapy to the doctors and patients around the world seeking another option for treating hypertension.

Get more information about how Paradise Ultrasound RDN can help your patients control high blood pressure

Provider Name(Required)
Address(Required)
Choose all that apply(Required)
References
  1. Azizi M. et al. Lancet. 2021 Jun 26;397(10293):2476-2486.
  2. Azizi M. JAMA. 2023;329(8):651-661
  3. Azizi M. et al. Lancet. 2018 Jun 9;391(10137):2335-2345.
  4. Zeijen et al. ACHIEVE Study, TCT 2023
  5. Kirtane A. et al. JAMA Cardiol. 2023;8(5):464-473

* Rx Only. Brief Summary – Prior to use, please reference the Instructions for Use

Indications for Use

The Paradise Ultrasound Renal Denervation System (Paradise System) is indicated to reduce blood
pressure as an adjunctive treatment in hypertension patients in whom lifestyle modifications and 
antihypertensive medications do not adequately control blood pressure.

Contraindications
The Paradise Catheter is contraindicated in any of the following:

  • Renal arteries diameter <3 mm and >8mm
  • Renal artery Fibromuscular disease (FMD)
  • Stented renal artery
  • Renal artery aneurysm
  • Renal artery diameter stenosis >30%
  • Pregnancy
  • Presence of abnormal kidney (or secreting adrenal) tumors
  • Iliac/femoral artery stenosis precluding insertion of the catheter
Warnings
  • Failure to use the recommended balloon size may result in renal artery stenosis,  dissection, perforation, 
aneurysm, significant vasospasm requiring intervention, ablation of unintended tissues or structures, 
and/or no ablation of target tissue achieved.
  • Energy emission in an unintended location may result in unintended tissue damage.
  • Do not move the Paradise Catheter during sonication.
  • Do not sonicate in renal artery at locations with visible plaque.
  • Do not deliver sonications in an overlapping arterial target zone
Precautions
  • Patients with known allergy to contrast medium may be at increased risk of hypersensitivity reactions.
  • Only use specified coolant (Sterile water) for fluid supply.  DO NOT USE SALINE.
  • Avoid multiple balloon inflations to achieve apposition of the balloon to the renal artery wall; multiple 
balloon inflations may result in increased vessel trauma.
  • The Paradise Catheter is for single use only.  Do not resterilize or reuse. Reuse, reprocessing, 
or resterilization will compromise device integrity which may result in patient injury, illness, or death.
  • Do not touch the Paradise Catheter balloon during sonication, as it may result in serious injury.
  • The Paradise System may interfere with or adversely affect the operation of cardiac pacemakers or other 
active implants, unless proper precautions have been taken or managed per the manufacturer’s 
instructions. When in doubt regarding possible hazards, seek qualified advice and/or consult with the 
manufacturer(s) prior to initiating a procedure.  The Paradise Catheter is a Type CF, defibrillation-proof 
Applied Part.Potential risks of renal denervation procedure/response to treatment Ablation or thermal injury to vessel, adjacent tissue or other structures, Acute kidney injury, Angina, 
Anxiety, Arrhythmia, Atrial tachycardia, Bradycardia, Gastrointestinal complications (diarrhea, nausea, 
vomiting), Hypotension/ Dizziness and/or Headaches, Hypertension, Hyperhidrosis, Pain (transient 
abdominal, lower back), Renal failure or renal insufficiency, Renal artery aneurysm or pseudoaneurysm, 
Renal infarction, Renal artery dissection, or perforation, Renal artery stenosis, Vasospasm, Vasovagal 
response, Stroke or transient ischemic event Potential risks of arterial catheterization procedure Allergic reaction to contrast, Arterio-enteric fistula, Arterio-venous fistula, Bleeding, Cardiopulmonary 
arrest, Complications related to pain and anti-anxiety medications, Death, Deep vein thrombosis, Edema, 
Embolism (pulmonary, renal, peripheral vasculature, plaque), Hematuria, Infection, Myocardial infarction, 
Pain, Vascular access site complications (pseudoaneurysm, pain, swelling, hematoma)