It’s not another pill, 
It’s another way.

Paradise blood pressure procedure, transforming uncontrolled resistant hypertension with 24-hour reduction, a meaningful blood pressure drop at 6 months, sustainable improvement for years to come.

References

  1. Jones D, et all, Hypertension, https://doi.org/10.1161/HYP.0000000000000249
  2. Kirtane A. et al. JAMA Cardiol. 2023;8(5):464-473
  3. Azizi M. et al. Lancet. 2018 Jun ;391(10137):2335-2345.
  4. Azizi M. et al. Lancet. 2021 Jun 26;397(10293):2476-2486.
  5. Azizi M. JAMA. 2023;329(8):651-661.
  6. Zeijen VJM Clin Res Cardiol. 2024.
  7. Fengler K. TCT-580. Presented at TCT 2025; October 2025
  8. Bloch et al. Hypertens Res. 2024.
  9. Redar et al. EuroIntervention 2022;18-online
  10. Zeijen VJM Clin Res Cardiol. 2024.

* Rx Only. Brief Summary – Prior to use, please reference the Instructions for Use

Indications for Use

The Paradise Ultrasound Renal Denervation System (Paradise System) is indicated to reduce blood pressure as an adjunctive treatment in hypertension patients in whom lifestyle modifications and antihypertensive medications do not adequately control blood pressure.

Contraindications

The Paradise Catheter is contraindicated in any of the following:

  • Renal arteries diameter <3 mm and >8 mm
  • Renal artery Fibromuscular disease (FMD)
  • Stented renal artery
  • Renal artery aneurysm
  • Renal artery diameter stenosis >30%
  • Pregnancy
  • Presence of abnormal kidney (or secreting adrenal) tumors
  • Iliac/femoral artery stenosis precluding insertion of the catheter.

Warnings

  • Failure to use the recommended balloon size may result in renal artery stenosis, dissection, perforation, aneurysm, significant vasospasm requiring intervention, ablation of unintended
tissues or structures, and/or no ablation of target tissue achieved.
  • Energy emission in an unintended location may result in unintended tissue damage.
  • Do not move the Paradise
Catheter during sonication.
  • Do not sonicate in renal artery at locations with visible plaque.
  • Do not deliver sonications in an overlapping arterial target zone.

Precautions

  • Patients with known allergy to contrast medium may be at increased risk of hypersensitivity reactions.
  • Only use specified coolant (Sterile water) for fluid supply. DO NOT USE SALINE.
  • Avoid multiple balloon inflations to achieve apposition of the balloon to the renal artery wall; multiple balloon inflations may result in increased vessel trauma.
  • The Paradise Catheter is for single use only. Do not resterilize or reuse. Reuse, reprocessing, or resterilization will compromise device integrity which may result in patient injury, illness, or death.
  • Do not touch the Paradise Catheter balloon during sonication, as it may result in serious injury.
  • The Paradise System may interfere with or adversely affect the operation of cardiac pacemakers or other active implants, unless proper precautions have been taken or managed per the manufacturer’s instructions. When in doubt regarding possible hazards, seek qualified advice and/or consult with the manufacturer(s) prior to initiating a procedure. The Paradise Catheter is a Type CF, defibrillation-proof Applied Part.

Potential risks of renal denervation procedure/response to treatment 
Ablation or thermal injury to vessel, adjacent tissue or other structures, Acute kidney injury, Angina, Anxiety, Arrhythmia, Atrial tachycardia, Bradycardia, Gastrointestinal complications (diarrhea, nausea, vomiting), Hypotension/ Dizziness and/or Headaches, Hypertension, Hyperhidrosis, Pain (transient abdominal, lower back), Renal failure or renal insufficiency, Renal artery aneurysm or pseudoaneurysm, Renal infarction, Renal artery dissection, or perforation, Renal artery stenosis, Vasospasm, Vasovagal response, Stroke or transient ischemic event 

Potential risks of arterial catheterization procedure 
Allergic reaction to contrast, Arterio-enteric fistula, Arterio-venous fistula, Bleeding, Cardiopulmonary arrest, Complications related to pain and anti-anxiety medications, Death, Deep vein thrombosis, Edema, Embolism (pulmonary, renal, peripheral vasculature, plaque), Hematuria, Infection, Myocardial infarction, Pain, Vascular access site complications (pseudoaneurysm, pain, swelling, hematoma)

© 2025 Recor Medical, Inc. All rights reserved. RECOR MEDICAL, PARADISE, RADIANCE, HYDROCOOLING, SONOWAVE 360 are trademarks of Recor Medical, Inc. The Paradise® System is FDA approved for sale in the United States, is CE marked and approved for sale in markets where the CE mark is accepted per approved indications for use, and received manufacturing and marketing approval in Japan.